實戰 15:萬用示波器第一部分: 寶馬 X5 蓄電池漏電


It’s not only on engine management within a vehicle where an oscilloscope delivers interesting finds: you can pretty much back-probe any wire and record a usable trace. You often find circuit operational characteristics that are not available in any OEM manual, and it’s this knowledge-building which is absolute gold. However, the only way to get truly proficient with an oscilloscope is to teach yourself, and this requires some investment of your time.

I’ve compiled a couple of recent investigations which are a world away from ignition or injection and demonstrate the oscilloscope as a versatile fault-finding tool. Any hardened “petrol head” may want to look away now.

BMW X5 Battery Drain

This BMW had a complaint of intermittent no start caused by the vehicle battery discharging. Sometimes it would last two weeks and other times only last two days. The battery had already been replaced, twice, and the alternator overhauled and given a clean bill of health. The garage involved reported that each time the vehicle was checked for parasitic draw, none was found: a nightmare scenario, so where do you start?

BMWs are famous for their long shut-down times and purely from my own experience I expect somewhere between 16 and 18 minutes before sleep mode is reached. This wait-time is a real headache when trying to fault-find because, until you have allowed enough time to expire, you could end up chasing a problem that doesn’t exist. Furthermore, start tracing too early by pulling or replacing circuit fuses and you’re likely to reset a controller, adding more wait-time. Easy this, isn’t it?

Cut to the fault. Executing a simple parasitic draw test at the battery, I eventually picked up on sporadic surges in current draw that didn’t fit with all previous shutdown patterns, with the ammeter recording surges as high as 5 amps. Through different tracing techniques I narrowed the search to the AC system and in particular the interior blower.

interior blower circuit

The blower regulator receives constant battery power and relies on a single information line from the heater controller to increase or decrease motor speed. This information arrives at the regulator in the form of a varying DC voltage where 0 V equals full off. At rest the motor receives +12 V permanently and relies on the regulator to vary the ground level applied, thus varying the motor speed.

I hooked up the scope to the blower regulator and set it recording:

figure 1

waveformTo obtain some suitable readings for analysis, Fig.1 was captured during a full speed sweep command. You can walk through the circuit operation starting with the speed request on CHC. As the request voltage increases, the regulator begins to supply a ground path for the motor creating a potential different across it; so the motor starts to turn. The speed request is incremental and likewise is the ground path applied to the motor.

Current flow on CHA follows a good trend as speed request increases, and closer inspection of commutation reveals a seemingly good motor. However, my attention was drawn to the part of the trace when speed was reducing, and current fluctuated as the regulator struggled to maintain a steady ground path. During this erroneous stage the speed request line held steady, which was evidence that the regulator was causing this particular anomaly. This was a real surprise as I didn’t hear or feel anything unusual through the air vents, so it was entirely down to the scope for spotting that. Although this shows that the regulator operation is incorrect during normal use, it hasn’t given anything conclusive towards our battery drain fault – yet.

An ammeter still monitoring parasitic draw coming straight out of the battery will give me a clear flag when the fault is present. So, hopefully, if the test plan so far has been correct, the scope should record some activity from the blower circuit.

The car was powered down as normal then left to settle. Waiting for a fault to appear can sometimes be a battle of patience, and this problem turned out to be no exception.

figure 2

It took some time before the vehicle decided to fail. Then the meter reading started to swing high, giving me a clear indication the fault was now present. Fig.2 was subsequently recorded and shows the fault clearly. The ground path from the regulator unit is starting to leak into the motor circuit, allowing a current path through the motor that creates an excessive burden on the battery. If this is happening all night long, that 3.0 diesel lump is going to be very disappointed in the morning. A new blower regulator was installed.

As stated at the outset, the use of an oscilloscope and the interpretation of the display are very educational. I come back to the discovery of “circuit operational characteristics” and its role in knowledge building: you get out what you put in.

 

請看第二部分 >

 

  400 999 3848 | sales@hkaco.com
  廣州虹科電子科技有限公司版權所有 | 科學城潤慧科技園C棟6層
汽車診斷示波器
汽車示波器
模塊
軟件
附件
資料庫和培訓
  輔導資料
  波形庫
  培訓課程
  應用案例和文章
技術支持
產品系列 公司介紹 培訓課程 新聞快報 聯系我們  
主站蜘蛛池模板: 在线一级黄色片| 亚洲女教师| 黄色三级毛片视频| 天天鲁天天玩天天爽天天| 毛色毛片免费观看| 国产成人精品日本亚洲直接| 精品老司机在线视频香蕉| yy6080久久国产伦理| 妖精视频一区二区三区| 精品国产中文字幕| 日本三级a做爰视频东爱| 久久精品视| 免费看一级毛片| 香港毛片在线观看| 国内拍拍自拍视频在线观看| 38pao强力打造永久免费高清视频| 成人在线观看免费爱爱| 国产精品久久网| 国产麻豆精品在线观看| 亚洲精品成人一区二区aⅴ| 久久亚洲精品一区成人| 成人黄色小视频| 国产成人aaa在线视频免费观看| 大狠狠大臿蕉香蕉大视频| 日韩伦理一区二区三区| www.黄色大片| 久久久网站| 亚洲一区二区三区四区| 欧美成人h版整片合集| 美国黄色一级毛片| 国产成人久久精品激情| 欧日韩一区二区三区| 1024在线播放| 99草视频| 日本亚洲色图| 成人5252色| 欧美第一精品| 国产精品日本一区二区不卡视频| 国产91久久精品一区二区| 国产免费观看视频| 国产九色在线|